Excellent service

Mark has been here before and knows the system

  • Overall Experience
  • Quality
  • Price
  • Convenience

Annual hvac service for ductless split and 3 ton central ac

Tech was nice, well dressed, was clear and concise about what he was doing, why he was doing it.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Julio was great. Fixed the issue and was very helpful with what I can do to prevent the problem in the future

  • Overall Experience
  • Quality
  • Price
  • Convenience

Nigel is great

Nigel was excellent

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

Gary and Lorenzo were great technicians - my house is warm again!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Review - Heating Annual Service

Great service, professional and friendly technicians

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Antonio went above and beyond to make sure all systems were in top shape for the season.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for new rochelle, ny

Mark E.

Mark E. Job Checkin

View visual findings from this job here - https://visionshare.xoi.io/?id=XA-57DC-12374C12E76F4E4FA4AD947C68022A47 Customer has no cooling on the first floor of their home from the space pack air with Lennox condensing unit: At Arrival the thermostat is off: * Call for cooling on the thermostat, but neither the indoor or outdoor unit are on and running * Check indoor air handler * System is showing an error for float switch * Reset error and system turns on * The drainage system on the first floor air handler is Completely backed up and full of sludge and debris * Spoke with customer over the phone as they are not home and got approval for repairs * Vacuum and brush primary pan 100% clean and clear * Vacuum vacuumed and brushed drain line and trap 100% clean and clear * Vacuumed and brushed condensate pump 100% clean and clear * Chemically treated primary pain and added condensate tablets * Tested all drainage- All water is flowing from inside primary pump through drain line into tr


Mark E.

Mark E. Job Checkin

Help Lorenzo install water heater Here to install 75 Gallon AO smith HWH Drain old existing HWH- Cut copper piping Disconnect gas line and remove to take out existing HWH Disconnect Flue/smoke pipe Remove old existing 75Gal AO Smith HWH Remove existing expansion tank and mixing valve. Installed new 75 Gallon AO Smith HWH Re-Connect copper piping hot, cold and mix Installed new expansion tank and mixing valve. Reconnect gas line. Check for leak w/ gas leak solution. No leak. Purge gas line. Installed flue/ smoke pipe Fire up HWH and set mixing valve to customer desire temperature. Purge all faucet hot and cold to remove air from all lines. Ran and monitor HWH all good View visual findings from this job here - https://visionshare.xoi.io/?id=XA-57DC-89F8E06E3D1C4772A457F67C918DB6B1


Mark E.

Mark E. Job Checkin

View visual findings from this job here - https://visionshare.xoi.io/?id=XA-57DC-D62A994A6F5840BEA2BBBC7DEF95BCBC Preform maintenance on x1 Carrier infinity gas fired furnace with bypass humidifier: * 6ft ladder needed to access system through x2 ceiling hatch’s * open furnace cabinet doors * shut power to system * removed flame sensor and hot surface igniter- cleaned sensor with copper bristle brush and polished clean with steel wool * inspected hot surface igniter- okay * brushed out and cleaned burner jet, furnace cabinet and components * inspected PVC fresh air and exhaust: okay * secured all electrical wiring and connections in furnace and blower cabinet * inspected blower motor/ wheel and assembly * removed condensate trap- flushed clean and primed with fresh water * removed neutralizer kit- has never been cleaned / replaced- customer approved * brought outside- dump minerals- washed and brushed clean- installed new minerals and put kit back together * reinstalled neutralizer


Gary P.

Gary P. Job Checkin

9/8 Performed blower test installed recessed light covers on 14 lights Air sealed light fixtures in ceiling and duct work penetrations Blocked chimneys with rockwool Installed rulers throughout attic Installed barrier wood for storage area Ran duct work for two bath fans Began air sealing rim joist in basement


Nigel  B.

Nigel B. Job Checkin

View visual findings from this job here - https://visionshare.xoi.io/?id=XA-EFBA-B361DE1B26C744DF96B2A2AE8B864DCB the system is two years old and homeowner is inquiring about the warranty office personnel please follow up


Nigel  B.

Nigel B. Job Checkin

View visual findings from this job here - https://visionshare.xoi.io/?id=XA-EFBA-D7BED79A961E4504BE7D9EFA45E0834D


will@innovativeairsolutions.com

will@innovativeairsolutions.com Job Checkin

Upon arrival client mentioned his concerns with recent installation. Checked UNICO system in basement, set thermostat to cooling and monitored operation. Noticed that return ductwork is being sucked in and expanding on shutdown due to static pressure differential. Checked filter noticed filter restricted. Uncommon filter size did not have on truck. Hand-crafted 10x20x1 Filter and Installed. Ran system ok, System is now quiet and not making any expansion noise from ducts. Checked return grille upstairs noticed that client has a bookshelf blocking return grille. Explained to client that this was also causing a restriction in the system due to inaccurate temperatures. Moved furniture for client as a courtesy. Recommended for client to purchase 10x20x1 filter and have us install each year for maintenance. While on-site collected check payment from client. Spoke to client about Heating service, client currently has oil fired boiler. AC System is currently operational and cooling well at thi


Nigel  B.

Nigel B. Job Checkin

to top off the system with refrigerant and inject ultraviolet dye to the first floor HVAC system View visual findings from this job here - https://visionshare.xoi.io/?id=XA-D510-02F3081FBE9242F1B2C5B2B7A8ED33FA


Richard  .

Richard . Job Checkin

Today I arrived on site to address the reported smell issues on a carrier furnace unit located on the basement. Initial Assessment: Investigated the musty smell reported in the bedroom air vents connected to the AC and Heating system. Fault Confirmation: Confirmed there is not musty smell coming from the 1st floor air vent or 2nd floor aire vents as described by the client.Upon arriving at the property. The client mentioned that sometimes she perceives a musty smell in some air vents of the rooms on the second floor. The client directed me to the basement where the unit is installed. I immediately noticed that the client has two cat litter boxes in front of the unit. The client made room for me to verify the unit. I proceeded to verify the furnace unit. I didn't perceive any strange smell inside the unit. I proceeded to check the evap coil. The Evap coil is clean, I didn't notice any strange smell in the Evap coil either. I proceeded to run the system and monitor it. The sys


Gary P.

Gary P. Job Checkin

Checked all previous work from yesterday to make sure everything is functioning Prepped garage floor and walls Drilled holes in garage ceiling Air sealed all gaps and penetrations in garage ceiling Dense packed cellulose in garage ceiling Patched all holes with netting and one coat compound Checked inside to make sure no blow thru Performed blower test Cleaned up garage and hosed down driveway Collected check


Richard  .

Richard . Job Checkin

AC System. Today, I arrived on site to perform an A/C system tune-up and cleaning. Here's what I did: Checked the blower motor and thermostat for proper operation-okay. Air filter: replaced. 16x30x1 14x25x1 Checked and cleaned the exterior jacket and interior cabinet-okay. Found the blower wheel-okay. Checked the ductwork-okay Washed and cleaned the indoor Evap coil. Checked and cleaned condensate pump and drain line, treating it with anti-algae. Monitored the refrigerant operating pressures-okay. The refrigerant type is 1x) R410A. Inspected the safety devices and found them to be operating properly. Inspected the electrical disconnect box for safe installation-okay. Inspected and tightened electrical wiring connections-okay. Tested and inspected the contact, which is not burned Inspected the electrical for exposed wiring-okay Inspected and tested the capacitors-okay. Inspected the fan blade-okay. Cleaned the condenser coil and removed debris. Checked the service valves for proper oper


Mark E.

Mark E. Job Checkin

Preform maintenance on x1 Carrier infinity gas fired furnace with bypass humidifier: * 6ft ladder needed to access system through x2 ceiling hatch’s * open furnace cabinet doors * shut power to system * removed flame sensor and hot surface igniter- cleaned sensor with copper bristle brush and polished clean with steel wool * inspected hot surface igniter- okay- replaced last season * brushed out and cleaned burner jet, furnace cabinet and components * inspected PVC fresh air and exhaust: okay * secured all electrical wiring and connections in furnace and blower cabinet * inspected blower motor/ wheel and assembly * removed condensate trap- flushed clean and primed with fresh water * removed neutralizer kit- inspected line stone minerals- okay- flushed clean * preform full condensate pump cleaning * reinstalled neutralizer kit, condensate trap and all drainage and tested for leaks- none * replaced air filter and humidifier water panel- open bypass damper * cleaned and flushed humidifie


Gary P.

Gary P. Job Checkin

Prepped kitchen area Covered remaining lights in attic floor Blew insulation in kitchen attic and behind foil on kneewall Filled slopes in staircase ceiling holes Repaired all holes Insulated exposed rim joist with rockwool and foam Fishished insulating exposed duct work in garage


julio@innovativeairsolutions.com

julio@innovativeairsolutions.com Job Checkin

View visual findings from this job here - https://visionshare.xoi.io/?id=XA-853F-F6286883CD8348068B0F9A2F25301DBC


Richard  .

Richard . Job Checkin

Perform heating maintenance on Buderus boiler with Hydro air handler, radiant heat zone, and indirect tank: Boiler : shop power to boiler Removed boiler covered doors- system, full of dust and debris Vacuum and dusted out boiler cabinet and components, under heat exchanger, burner tubes, and piping Removed pilot assembly, and spark igniter from boiler Clean spark igniter with copper bristle brush, and polished clean with steel wool Reinstalled and secured all connections Test expansion tank, water feed, and backflow preventer, air vent, and relief valve- okay Secured and inspected electrical wiring and components Inspect flue piping and damper motor- okay Polished and wiped down all equipment Return power to system Test take zoning panel, securing all connections- test Hydro and radiant heating thermostat- zone panel response, circulator pumps on and running and boiler fires Monitor system operations, flames, boiler pressure and temperature- normal Boiler satisfies at 180° Tested dome